How to prevent perforation and damage of medical gloves
Medical gloves have become essential items in hospitals as they can effectively isolate medical contamination and prevent cross infection between doctors and patients. In clinical practice, especially in surgeries with infection risks, medical staff are concerned about the damage or perforation of medical gloves, which is a common problem during surgery, especially in orthopedic and plastic surgery. There are many factors that can cause damage or perforation of medical gloves, such as instrument injuries, bone tissue punctures, and ruptures caused by decreased glove strength. Larger areas of damage are easily detected, while smaller perforations are often difficult to detect, and the risk of cross infection is hidden. Therefore, it is necessary to test the puncture resistance of medical gloves in advance. The puncture resistance of 2 # medical gloves is good, while the puncture resistance of 3 # medical gloves is poor. During use, they are extremely prone to perforation and damage when encountering sharp objects such as Kirschner wires and ligature wires.
In order to prevent this risk, many medical staff choose to wear double-layer medical gloves to resist the perforation and rupture of medical gloves. According to research and statistics, after using this method, the perforation rate of inner gloves is only about 10% of that of single-layer gloves. However, after wearing double-layer medical gloves, the flexibility and sensitivity of fingers significantly decrease, which to some extent affects the accuracy of surgery and artificially increases the risk of surgery. Therefore, the fundamental solution is still to strictly monitor the quality of medical gloves before use, ensuring that their puncture force can reach a certain strength, reducing the risk of perforation and damage of medical gloves in clinical practice, and reducing the risk of clinical cross infection between doctors and patients.
While ensuring the good quality of medical gloves, medical staff should also replace them in a timely manner based on their actual use. After conducting a statistical study on the damage of medical gloves used by medical staff, it was found that after continuous use of gloves for 4 hours, the damage rate of medical gloves significantly increased and had concealment. Therefore, medical gloves should be replaced in a timely manner. And some types of surgeries, such as open surgery,
其渗出液、油脂、胆汁、胰液等会对医用手套产生腐蚀作用,导致手套老化加速,性能减退,应根据实际情况及时检查更换医用手套。